Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

These runtime constraint handlers mitigate some of the potential insecurity caused by in-band error indicators (see ERR02-AC. Avoid in-band error indicators).

Non-Compliant Code Example (TR24731-1)

...

Wiki Markup
\[[ISO/IEC TR 24731-1:2007|AA. C References#ISO/IEC TR 24731-1-2007]\] Section 6.1.4, "Runtime-constraint violations", and Section 6.6.1, "Runtime-constraint handling"
\[[MSDN|AA. C References#MSDN]\] "[Parameter Validation|http://msdn.microsoft.com/en-us/library/ksazx244.aspx]"

...

ERR02-A. Avoid in-band error indicatorsImage Added      12. Error Handling (ERR)       ERR04-A. Choose an appropriate termination strategy