Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Added PC-lint Plus to Automated Detection Table

...

Tool

Version

Checker

Description

Astrée
Include Page
Astrée_V
Astrée_V
memcmp-with-floatPartially checked
Axivion Bauhaus Suite

Include Page
Axivion Bauhaus Suite_V
Axivion Bauhaus Suite_V

CertC-FLP37Fully implemented
LDRA tool suite
Include Page
LDRA_V
LDRA_V
618 SEnhanced Enforcement
Parasoft C/C++test

Include Page
Parasoft_V
Parasoft_V

CERT_C-FLP37-c

Do not use object representations to compare floating-point values

PC-lint Plus

Include Page
PC-lint Plus_V
PC-lint Plus_V

2498, 2499

Fully supported

Polyspace Bug Finder

Include Page
Polyspace Bug Finder_V
Polyspace Bug Finder_V

CERT C: Rule FLP37-CChecks for memory comparison of floating-point values (rule fully covered)
PRQA QA-C

Include Page
PRQA QA-C_v
PRQA QA-C_v

5026 
PVS-Studio

Include Page
PVS-Studio_V
PVS-Studio_V

V1014
RuleChecker

Include Page
RuleChecker_V
RuleChecker_V

memcmp-with-floatPartially checked
TrustInSoft Analyzer

Include Page
TrustInSoft Analyzer_V
TrustInSoft Analyzer_V


Exhaustively verified.

...