SEI CERT C++ Coding Standard
2 Rules
Rule 49. Miscellaneous (MSC)
MSC54-CPP. A signal handler must be a plain old function
Page Information
Title:
MSC54-CPP. A signal handler must be a plain old function
Author:
Aaron Ballman
Jan 29, 2015
Last Changed by:
Anirban Gangopadhyay
Dec 01, 2023
Tiny Link:
(useful for email)
https://wiki.sei.cmu.edu/confluence/x/GHs-BQ
Export As:
Word
·
PDF
Hierarchy
Parent Page
Page:
Rule 49. Miscellaneous (MSC)
Labels
Global Labels (9)
notes
review-dms
nptc
review
rule
no-autodetect
review-ajb
msc
nptc-complexity
Recent Changes
Time
Editor
Dec 01, 2023 16:54
Anirban Gangopadhyay
View Changes
Apr 20, 2023 04:56
Jill Britton
View Changes
Apr 27, 2022 09:31
Jill Britton
View Changes
Apr 26, 2021 11:37
Jill Britton
View Changes
Apr 26, 2021 06:18
Jill Britton
View Page History
Outgoing Links
External Links (7)
https://www.mathworks.com/help/bugfinder/ref/certcmsc54cpp.…
https://wiki.sei.cmu.edu/confluence/pages/viewpage.action?p…
https://wiki.sei.cmu.edu/confluence/pages/viewpage.action?p…
https://wiki.sei.cmu.edu/confluence/pages/viewpage.action?p…
https://www.securecoding.cert.org/confluence/display/cplusp…
https://www.kb.cert.org/vulnotes/bymetric?searchview&query=…
https://wiki.sei.cmu.edu/confluence/display/cplusplus/Polys…
SEI CERT C++ Coding Standard (9)
Page:
BB. Definitions
Page:
Klocwork_V
Page:
Helix QAC_V
Page:
Parasoft_V
Page:
AA. Bibliography
Page:
Polyspace Bug Finder_V
Page:
Parasoft
Page:
Helix QAC
Home page:
SEI CERT C++ Coding Standard
SEI CERT C Coding Standard (3)
Page:
SIG31-C. Do not access shared objects in signal handlers
Home page:
SEI CERT C Coding Standard
Page:
SIG30-C. Call only asynchronous-safe functions within signal handlers
Overview
Content Tools
{"serverDuration": 103, "requestCorrelationId": "d93b51cc1b923bb4"}