The logical AND and logical OR operators (&&, ||) exhibit "short circuit" operation. That is, the second operand is not evaluated if the result can be deduced solely by evaluating the first operand. Therefore, the second operand should not contain side effects since, if it does, it will not be apparent whether the side effects happen.

Non-Compliant Code Example

int i;
int max;
...
if ( (i >= 0 && (i++) <= max) ) {
...
}

It is unclear whether the value of i will be incremented as a result of evaluating the condition.

Compliant Solution

In this compliant solution, the behavior is much clearer.

int i;
int max;
...
if ( (i >= 0 && (i + 1) <= max) ) {
  i++;
...
}

Risk Assessment

Attempting to modify an object that is the second operand to the logical OR or AND operator may cause that object to take on an unexpected value. This can lead to unintended program behavior.

Rule

Severity

Likelihood

Remediation Cost

Priority

Level

EXP02-A

1 (low)

1 (unlikely)

3 (low)

P3

L3

References

[[ISO/IEC 9899-1999]] Section 6.5.13, "Logical AND operator," and Section 6.5.14, "Logical OR operator"